1
Hi, Guest!

  LOKASI :  Jakarta Pusat

  AKTIVITAS :  20 hours ago

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
SUMBER BERKAT ABADI GOOD QUALITY WITH COMPETITIVE PRICE. GUARANTEE YOU SATISFIED 100%

Woodward GCP-30 Series P/N 8440-1199 GCP-31

Update Terakhir
:
22 / 06 / 2019
Min. Pembelian
:
1 Set
Harga Mulai
Rp. 78.888.000
Sampai dengan
Rp. 78.999.000
Bagikan
:

Sumber Berkat Abadi, We Are Specialist For Auto Synchronous Generators, Battery Chargers, AVR, Solenoid, Starter Motor, COS & Spare Parts Generators :


 


- Modul Synchronous, Load Sharing & Speed Control = WOODWARD, Deepsea DSE, Smart Gen. Comap, Datakom


- Battery Charger = BAE, SEG, CSS, Firetroll, BAC, DSE, SMPS


- COS = Kyoritsu, Takada & Socomec.


- AVR = Stamford, Basler, OEM, & Leroy Somer


- Starter Motor = Bosch, Hitachi, Mahle, etc

- Solenoid = Woodward, OEM,

- etc


Sonny Pranata


HP / WA : 08788 24 000 19

Detail Woodward GCP-30 Series P/N 8440-1199 GCP-31

Woodward GCP-30 Series P/N 8440-1199 GCP-31

GCP-30

 

Woodward’s Genset Control For Multiple/Parallel Operation Provides Reliability

Woodward’s GCP-30 Series genset controllers are designed to provide total control for multiple, medium- to large-sized applications. A network of the compact, versatile GCP-30 controls is capable of controlling up to 14 gensets with automatic sequencing. Load management features include automatic base loading/peak shaving, import/export control, and emergency power/back up power generation. The GCP-30 Series is well known in the market for highly reliable soft- and hardware.

Features include:

  • True RMS voltage and current sensing for Generator, Bus, and Mains
  • Complete engine/generator protection, plus mains monitoring
  • Relay manager for programming relay outputs according to selectable discrete and analog conditions
  • Load share 14 gensets in island mode or paralleled to the utility
  • Different load or process dependent start/stop sequencing modes with active and reactive power load sharing
  • Communication to engine ECU’s (CAT, MDEC, J1939 based protocols), PLC’s, external I/O extension cards
  • Connection to Woodward LS4 to run multiple breaker applications
  • Configurable discrete Inputs and Relay Outputs



Specifications

Power supply

12/24Vdc (9.5 to 32 Vdc)

Consumption

max. 20W

Ambient temperature (storage)

-30 to 80 °C

Ambient temperature (operation)

-20 to 70 °C

Ambient humidity

95 %, non-condensing

Voltage AC input

120Vac and 480Vac true RMS

Accuracy

Class 1

Current AC input

1A or 5A true RMS, isolated

Accuracy Iac

Class 1

Discrete inputs (isolated)

Range: 12/24Vdc (6 to 32Vdc)

Relay outputs

Relays, dry contacts

Load (resistive)

2A@24Vdc and 250Vac

Analog inputs

0/4 to 20mA

Analog outputs (isolated)

0/4 to 20 mA (freely scalable)

Housing

 

Front panel mounting

Plastic housing

Dimension (WxHxD)

144 × 144 × 118 mm

Sealing (front/back)

IP42/IP21

Weight

Approx. 1,850 g (depending on model)

Tampilkan Lebih Banyak
sumber berkat abadi
sumber berkat abadi

Sumber Berkat Abadi

PREMIUM GOLD 5 Tahun
Jl. Pintu Air 3 No. 25-C Pasar Baru, Jakarta Pusat
Indonesia 10710
Jakarta Pusat
14 / 10 / 2019
Hubungi Kami

Detail Woodward GCP-30 Series P/N 8440-1199 GCP-31

Woodward GCP-30 Series P/N 8440-1199 GCP-31

GCP-30

 

Woodward’s Genset Control For Multiple/Parallel Operation Provides Reliability

Woodward’s GCP-30 Series genset controllers are designed to provide total control for multiple, medium- to large-sized applications. A network of the compact, versatile GCP-30 controls is capable of controlling up to 14 gensets with automatic sequencing. Load management features include automatic base loading/peak shaving, import/export control, and emergency power/back up power generation. The GCP-30 Series is well known in the market for highly reliable soft- and hardware.

Features include:

  • True RMS voltage and current sensing for Generator, Bus, and Mains
  • Complete engine/generator protection, plus mains monitoring
  • Relay manager for programming relay outputs according to selectable discrete and analog conditions
  • Load share 14 gensets in island mode or paralleled to the utility
  • Different load or process dependent start/stop sequencing modes with active and reactive power load sharing
  • Communication to engine ECU’s (CAT, MDEC, J1939 based protocols), PLC’s, external I/O extension cards
  • Connection to Woodward LS4 to run multiple breaker applications
  • Configurable discrete Inputs and Relay Outputs



Specifications

Power supply

12/24Vdc (9.5 to 32 Vdc)

Consumption

max. 20W

Ambient temperature (storage)

-30 to 80 °C

Ambient temperature (operation)

-20 to 70 °C

Ambient humidity

95 %, non-condensing

Voltage AC input

120Vac and 480Vac true RMS

Accuracy

Class 1

Current AC input

1A or 5A true RMS, isolated

Accuracy Iac

Class 1

Discrete inputs (isolated)

Range: 12/24Vdc (6 to 32Vdc)

Relay outputs

Relays, dry contacts

Load (resistive)

2A@24Vdc and 250Vac

Analog inputs

0/4 to 20mA

Analog outputs (isolated)

0/4 to 20 mA (freely scalable)

Housing

 

Front panel mounting

Plastic housing

Dimension (WxHxD)

144 × 144 × 118 mm

Sealing (front/back)

IP42/IP21

Weight

Approx. 1,850 g (depending on model)

Tampilkan Lebih Banyak