1
Hi, Guest!

  LOKASI :  Jakarta Pusat

  AKTIVITAS :  18 minutes ago

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
SUMBER BERKAT ABADI GOOD QUALITY WITH COMPETITIVE PRICE. GUARANTEE YOU SATISFIED 100%

Protection Relay SEG RW N 1-10-230 - BERGARANSI 3 BULAN

Update Terakhir
:
08 / 11 / 2019
Min. Pembelian
:
1 Unit
Harga Mulai
Rp. 3.380.000
Sampai dengan
Rp. 3.400.000
Bagikan
:

Sumber Berkat Abadi, We Are Specialist For Auto Synchronous Generators, Battery Chargers, AVR, Solenoid, Starter Motor, COS & Spare Parts Generators :


 


- Modul Synchronous, Load Sharing & Speed Control = WOODWARD, Deepsea DSE, Smart Gen. Comap, Datakom


- Battery Charger = BAE, SEG, CSS, Firetroll, BAC, DSE, SMPS


- COS = Kyoritsu, Takada & Socomec.


- AVR = Stamford, Basler, OEM, & Leroy Somer


- Starter Motor = Bosch, Hitachi, Mahle, etc

- Solenoid = Woodward, OEM,

- etc


Sonny Pranata


HP / WA : 08788 24 000 19

Detail Protection Relay SEG RW N 1-10-230 - BERGARANSI 3 BULAN

Reverse Power Relay SEG RW N 1-10-230 - BERGARANSI 3 BULAN

DIJAMIN ANDA PUAS 100%

BERGARANSI selama 3 BULAN
Jika Rusak / Tidak Berfungsi, maka Modul kami Ganti Baru
(Bukan di Repair / diperbaiki, Namun GANTI MODUL BARU)

Garansi Tidak Berlaku, jika :
- Salah Pemasangan
- Komponen Terbakar
- Induksi Petir

  • Brand: SEG
  • Product Code: RW N 1-10-230
  • Weight: 1kg

Application
Under- and over-frequency supervision of single or three-phase systems.

Function
The unit BF1 is equipped with an independent over (f>) and under-frequency supervision (f<) with separate adjustable pickup values and trip delays.
The measured frequency is continuously compared with the set reference values.
For frequency supervision the cycle duration is evaluated and so measuring is virtually independent on harmonics. 
To avoid tripping during normal operation due to interference voltages, a fixed measuring repetition is used.

Technical Data

rate voltage Un: 110V, 230V, 400 V AC
frequency range at 
50 Hz rated frequency                : 46 - 54 Hz
60 Hz rater frequency                 : 55,2 - 64,8 Hz
hysteresis                                      : 0,5% of nominal frequency
power consumption                    : 3,7 VA
thermal load carrying capacity  : continuously 1,3 x Un
returning time                              : 250 ms
minimum operating time           : 250 ms

Output relays:
max. breaking capacity ohm ic  : 250 V AC/120 W DC
inductive                                        : 500 V AC/75 W DC
rated current                                : 5 A
making current                            : 20 A

System data:

regulations                                    : VDE 0435 part 303
temperature range 
at storage and operation            : - 25 0C bis + 70 0C

Mechanical stress:
shock                                              : class 1 acc. to DIN IEC 255-21-2
vibration                                        : class 1 acc. to DIN IEC 255-21-1
degree of protection                   : IP 40 at closed front cover
weight                                            : approx. 0,5 kg
mounting position                        : any

The unit BF1 is designed to be fastened onto a DIN rail acc. to DIN EN 50022 same as all units of the BASIC LINE.
The front plate of the unit is protected with a salable transparent cover (IP40)
Please remove the transparent cover with a screw driver to adjust the relay.

LEDs
LED f< is used to indicate operation without fault with steady light. LEDs f> and f< indicate pickup of the relay by flashing.
at under-frequency tripping LED f< extinguishes. LED f> indicates tripping at over-frequency (steady light).

perlengkapan listrik lainnya

Tampilkan Lebih Banyak
sumber berkat abadi
sumber berkat abadi

Sumber Berkat Abadi

PREMIUM GOLD 5 Tahun
Jl. Pintu Air 3 No. 25-C Pasar Baru, Jakarta Pusat
Indonesia 10710
Jakarta Pusat
17 / 11 / 2019
Hubungi Kami

Detail Protection Relay SEG RW N 1-10-230 - BERGARANSI 3 BULAN

Reverse Power Relay SEG RW N 1-10-230 - BERGARANSI 3 BULAN

DIJAMIN ANDA PUAS 100%

BERGARANSI selama 3 BULAN
Jika Rusak / Tidak Berfungsi, maka Modul kami Ganti Baru
(Bukan di Repair / diperbaiki, Namun GANTI MODUL BARU)

Garansi Tidak Berlaku, jika :
- Salah Pemasangan
- Komponen Terbakar
- Induksi Petir

  • Brand: SEG
  • Product Code: RW N 1-10-230
  • Weight: 1kg

Application
Under- and over-frequency supervision of single or three-phase systems.

Function
The unit BF1 is equipped with an independent over (f>) and under-frequency supervision (f<) with separate adjustable pickup values and trip delays.
The measured frequency is continuously compared with the set reference values.
For frequency supervision the cycle duration is evaluated and so measuring is virtually independent on harmonics. 
To avoid tripping during normal operation due to interference voltages, a fixed measuring repetition is used.

Technical Data

rate voltage Un: 110V, 230V, 400 V AC
frequency range at 
50 Hz rated frequency                : 46 - 54 Hz
60 Hz rater frequency                 : 55,2 - 64,8 Hz
hysteresis                                      : 0,5% of nominal frequency
power consumption                    : 3,7 VA
thermal load carrying capacity  : continuously 1,3 x Un
returning time                              : 250 ms
minimum operating time           : 250 ms

Output relays:
max. breaking capacity ohm ic  : 250 V AC/120 W DC
inductive                                        : 500 V AC/75 W DC
rated current                                : 5 A
making current                            : 20 A

System data:

regulations                                    : VDE 0435 part 303
temperature range 
at storage and operation            : - 25 0C bis + 70 0C

Mechanical stress:
shock                                              : class 1 acc. to DIN IEC 255-21-2
vibration                                        : class 1 acc. to DIN IEC 255-21-1
degree of protection                   : IP 40 at closed front cover
weight                                            : approx. 0,5 kg
mounting position                        : any

The unit BF1 is designed to be fastened onto a DIN rail acc. to DIN EN 50022 same as all units of the BASIC LINE.
The front plate of the unit is protected with a salable transparent cover (IP40)
Please remove the transparent cover with a screw driver to adjust the relay.

LEDs
LED f< is used to indicate operation without fault with steady light. LEDs f> and f< indicate pickup of the relay by flashing.
at under-frequency tripping LED f< extinguishes. LED f> indicates tripping at over-frequency (steady light).